PRODUCT'S AND MANUALS
MULTI-LOOP- ADDRESSABLE FIRE ALARM CONTROL PANEL- MODEL- DE-ML-9DAi
- Supports 2,56,000 devices in any combination.
- Peer to Peer network communication up to 64 control units.
- CANBUS, MODBUS, RS485 enabled.
- 4.3″ LCD/LED/TFT display.
- 48 hours inbuilt battery backup with SMPS.
- Duplicate address sensing.
- EN54, CE Complied.
2- LOOP ADDRESSABLE FIRE ALARM CONTROL PANEL- MODEL-DE-LB-9DAi
- Supports up to 500 devices in any combination.
- 1024 programmable MODBUS points.
- 128 zones for enhanced addressability.
- 7000 events log.
- Peer to Peer communication
- EN54, CE Complied.
ADDRESSABLE HEAT AND SMOKE MULTI-CRITERIA DETECTOR- MODEL-DE-HSD-9Di
- Dual LED indicators for 360 degree view.
- Low standby current.
- Soft addressing using hand-held programmer.
- Fixed heat and Rate of Rise enabled.
- Two wire SLC connection.
- Removable Sensing Chamber for easy maintenance.
- EN54 complied.
ADDRESSABLE SMOKE DETECTOR -MODEL- DE-SD-9Di
- Inbuilt response indicator output.
- Microcontroller based processing, eliminate false alarm.
- Removable sensing chamber for easy maintenance.
- Highly sensitive Infrared photo Sensor.
- EN54 Complied.
- Four level sensitivity, detector sensitivity can be programmed through control panel.
ADDRESSABLE HEAT DETECTOR- MODEL- DE-HD-9Di
- Stable communication technique with noise immunity.
- Semi-Conductor based highly sensitive detection of fixed heat and ROR.
- Dual LED indication for wider view.
- Remote test facility through panel.
- EN54 Complied.
ADDRESSABLE CONTROL MODEULE- MODEL- DE-CM-Di
- Built-in type identification automatically identifies third party devices to the control panel.
- Wide viewing angle of LED.
- Available in 1 way & 2 way module. Compatible with DAKSH panel.
- Micro controller based device. Low standby current.
- Fully confirms IS: 2189
- Automatic relay reset.
ADDRESSABLE INPUT MODULE- MODEL- DE-IM-9Di
- Wide viewing angle of LED.
- Soft addressable by use of address programmer
- Addressable –analog communication
- Available in 1/ 2/ 4/ 6 Zone module
- Micro controller based device
- Fully confirms IS: 2189
- Robust Mild Steel body
ADDRESSABLE MONITOR MODULE-MODEL-DE-MM-9Di
- Up to Two Addressable initiating device circuits
- Input Devices Automatically Reset when panel resets or in case of power failure.
- Wide viewing angle of LED.
- Soft addressable by use of address programmer.
- Addressable –analog communication.
- Available in 1/2/4/6/8 Zone module.
- Micro controller based device.
- Low standby current.
- fully confirms IS: 2189
ADDRESSABLE MANUAL CALL POINT- MODEL- DE-MCP-9Di
- Sends manual alarm signal to control panel via 2-wire bus.
- High reliability and wide range application.
- Push- type operation to avoid frequently changing classes.
- Super-thin structure design.
- Key Protected manual fire initiation Device.
- One red LED indication.
ADDRESSABLE HOOTER CUM FLASHER- MODEL- DE-HTR-9Di
- 24 Volt DC operation High Sound output Flash indication.
- ABS Plastic Body Wall mounted type Attractive look
- Suitable for Mall, Bank, Restaurant etc Suitable for sound polluted areas
- Low power consumption
- Fully confirms IS: 2189
- Sound output 90db at 1 meter
ADDRESSABLE FAULT/LOOP ISOLATOR
- Isolate loop/device in case of wire to wire short circuit.
- No reset or replacement required.
- The Isolator shall mount in a detector base.
- Fully confirms IS: 2189
ADDRESSABLE REPEATER PANEL MODEL- DE-REP-9i
- Inbuilt response indicator output.
- Microcontroller based processing, eliminate false alarm.
- Removable sensing chamber for easy maintenance.
- Highly sensitive Infrared photo Sensor.
- EN54 Complied.
- Four level sensitivity, detector sensitivity can be programmed through control panel.
DAKSH’S CONVENTIONAL FIRE DETECTION & ALARM SYSTEMS
8-32 ZONE CONVENTIONAL FIRE ALARM CONTROL PANEL- MODEL- DAKSH RIGAL
- Supports 800 devices in any combination.
- Inbuilt highly efficient power supply.
- On-board programming using integral keyboard.
- Auto reset supervisory operation.
- Event log with date and time stamp using RTC.
- On board system test facility.
- RS-485 communication.
12 ZONES CONVENTIONAL FIRE ALARM CONTROL PANEL- MODEL- DAKSH VISION
- Supports upto 300 devices.
- PA system interface.
- Upto 2 dry contact relay output.
- EMI/EMC proof.
- 3K3 ohms end of line resistor.
- Inbuilt Power supply.
- Facilities like reset, silence and lamp test availab
CONVENTIONAL SMOKE DETECTOR- MODEL- DE-CSD
- Optical type smoke detector.
- Microcontroller based device, highly precise operation.
- Dual colour LED for fire and active indication.
- Easy Installation.
- ERTL approved.
- Fully confirms IS:2189.
CONVENTIONAL HEAT DETECTOR- MODEL- DE-CHD
- Thermistor based detection.
- Fixed heat cum rate of rise of temperature.
- Microprocessor based device.
- Dual LED indication for 360 degree view.
- Large operating voltage range.
- ERTL approved.
- Fully Confirms IS:2189
CONVENTIONAL HEAT & SMOKE MULTICRITERIA DETECTOR- MODEL- DE- CHSD
- Optical type smoke detection.
- Thermistor type fixed heat and rate of rise of temperature.
- Dual LED for wider view.
- Large operating temperature.
- ERTL approved.
- Fully confirms IS:2189.
CONVENTIONAL MANUAL CALL POINT- MODEL- DE-CMCP-ABS
- Red LED indication
- Safe & reliable
- Complimentary range of accessories
- Flush or surface mounting
- Available with or without internal resistor
- Front Protection Glass Cover
- fully confirms IS: 2189
CONVENTIONAL MANUAL CALL POINT- MODEL-DE-CMCP-MS
- Red LED indication
- Safe & reliable
- Complimentary range of accessories
- Flush or surface mounting
- Available with or without internal resistor
- fully confirms IS: 2189
- Easy installation
- Full Mild Steel body.
CONVENTIONAL HOOTER CUM FLASHER- MODEL- DE-HCF-MS
- 24 Volt DC operation
- Sound intensity of 85db to 110db
- MS CRCA Body
- Wall mounted type
- High Performance
- Flash indication.
- Easy Installation
- fully confirms IS: 2189
CONVENTIONAL HOOTER CUM FLASHER ABS- MODEL- DE-HCF-ABS
- 24 Volt DC operation
- High Sound output
- Flash indication.
- ABS Plastic Body
- Wall mounted type
- Suitable for Mall, Bank, Restaurant etc
- Suitable for sound polluted areas
- Low power consumption
- Fully confirms IS: 2189
CONVENTIONAL HOOTER (ABS)- MODEL- DE-HTR-ABS
- Low power consumption
- High Performance
- Dual tone audio.
- 100V AC Operation
- Inbuilt Line matching transformers (LMT) for PA System
- Easy Installation
- Fully confirms IS: 2189
CONVENTIONAL HOOTER(MS) – MODEL- DE-HTR-MS
- Low power consumption
- High Performance
- Frequency range of 500Hz to 1000Hz
- 100 Volt AC operation
- Inbuilt Line matching transformers (LMT) for PA System
- Fully confirms IS: 2189
- Easy Installation.
CONVENTIONAL REPEATER PANEL- MODEL- DE-RIGAL
- Inherently power limited.
- Works on 24V DC which comes from main panel.
- Integrals – voltmeter (DC voltage) indication in the LCD display itself.
- LED indications for alarm & fault
- Fast RS-485 communication protocol.
- CRCA sheet, Powder Coated Housing.
- Switches for RESET, SILENCE, EVACUATE.
- Easy Installation & Operation.
DAKSH’S PUBLIC ADDRESS SYSTEMS
PUBLIC ADDRESS SYSTEM CONTROL PANEL- MODEL- PDXM001
- Message manager
- 8-Zone outputs.
- 8- Trigger inputs and emergency control inputs.
- 8- Dry contact outputs.
- RS485/TCP/IP
- Inbuilt Bluetooth, USB, SD card for audio input.
- LCD/TFT display.
PUBLIC ADDRESS SYSTEM CALL STATION- MODEL- PDXC001
- 64 Zone for voice alarm system.
- LED indications for zone selection, fault, busy and emergency state.
- 220V AC supply.
- Low noise, selectable gain, speech filter enabled.
- All call key.
- Compatible with Daksh’s Public Address Controller.
PUBLIC ADDRESS SYSTEM AMPLIFIER(45W-250W)- MODEL- DE-AMP-9i(45W-250W)
- Designed for wide Public Address applications
- 45 to 250 watts mixer amplifier.
- Up-to 4 unbalanced independent mic inputs and 2 unbalanced mic inputs.
- Inbuilt circuit protection.
- Provisions for automatic changeover from AC to DC battery power supply.
- Inbuilt 100V line for distant speakers.
PUBLIC ADDRESS SYSTEM AMPLIFIER- MODEL- DE-AMP-9i(400W-500W)
- Ideal for use in wide variety of 2 zones public address applications.
- 2 zone amplifier with 6 independent imbalanced mic inputs & 2 aux inputs.
- Each Zone with independent tone.
- Stereo music inputs.
- Individual zone ON/OFF facility.
CEILING MOUNT SPEAKER FOR PUBLIC ADDRESS SYSTEM- MODEL- DE-CS-6″
- Power handling capacity of 6 watts
- High sound pressure level
- Inbuilt 100v line matching transformer.
- Optimized for music & speech applications
- Ideal for mounting in false ceiling
- Fully confirms IS:2189
WALL MOUNT SPEAKER FOR PUBLIC ADDRESS SYSTEM- DE-WM
- Power handling capacity of upto 18 watts
- High sound pressure level
- Inbuilt 100v line matching transformer.
- Optimized for music & speech applications
- Ideal for mounting in false ceiling
- Fully confirms IS:2189
PUBLIC ADDRESS SYSTEM HORN SPEAKER- MODEL- DE-HS
- High quality weather proof UV protected ABS housing suitable for outdoor applications.
- Sound output of 125 db
- 100 V line matching transformer.
- Fully confirms IS:2189
FIRE FIGHTER’S TELEPHONE JACK- MODEL- DE-FFTJ-ABS
- Standard telephone jack for direct communication with control unit.
- Wall-mount design.
- ABS body.
- Fully confirms IS;2189
FIRE FIGHTER’S TELEPHONE JACK- MODEL- DE-FFTJ-MS
- Standard telephone jack for direct communication with control room.
- Wall mount type.
- Full mild steel body.
- Fully confirms IS 2189
FIRE FIGHTER’S TELEPHONE- MODEL- DE-FFTJ-SS
- Standard mount type telephone jack.
- Stainless steel body.
- Fully confirms IS:2189
FIRE FIGHTING MASTER TALK BACK SYSTEM- MODEL- DAKSH-FFTS
- Expandable upto 64 zones
- Battery backup with inbuilt power supply.
- Transparent front glass for easy operation.
- Compact Size.
- Fully confirms IS:2189
DAKSH’S MOTORIZED SIREN MODEL- DE-SRN
- Compact and light weight.
- Inbuilt mounting clamps for easy installation.
- Range upto 2 KM
- Cast Aluminium housing.
- Standard siren tone.
- Fully confirms IS:2189
DAKSH’S NURSE/DOCTOR CALL SYSTEM
MAIN CONTROL PANEL- NURSE CALL SYSTEM- MODEL- DAKSH VISION NCS
- Based on Microcontroller
- Holder type LED indication of each call.
- Soft touch membrane type control switches
- Wall mounted configurations
- 12 VDC Operating Voltage
- ABS Body
- Easy and quick installation
- Networking system
DISPLAY UNIT- NURSE CALL SYSTEM- MODEL- DAKSH VISION- NCD
- Based on Microcontroller
- Soft touch membrane type control switches
- LED indication of each bed or room
- Wall mounted configurations
- Networkable panel
- CRCA Sheet with powder coating
BED SWITCH NURSE CALL SYSTEM- MODEL- DAKSH NCS BED SWITCH
- Based on Microcontroller
- Holder type LED indication of each call.
- Soft touch membrane type control switches
- Wall mounted configurations
- 12 VDC Operating Voltage
- ABS Body
- Easy and quick installation
- Networking system
DOME DISPLAY NURSE CALL SYSTEM MODEL- DE-NCS-DD
- Microcontroller based device.
- LED indication of each call.
- Wall mounted configurations
- 12 VDC Operating Voltage
- CRCA Sheet with powder coating
- Networking system
- Working mode: continuous
- 6 beds per dome light
TOILET CALL SWITCH MODEL- DAKSH VISION-NCS-TCS
- Based on Microcontroller
- Holder type LED indication of each call.
- Wall mounted configurations
- 12 VDC Operating Voltage
- ABS Body
- Easy and quick installation
- Networking system
- Working mode: consecutive